Journal of Surgical Research
Volume 141, Issue 2 , Pages 153-161, August 2007

Reduction of Post-Surgical Adhesion Formation with Tranilast

  • Kevin Cooper, Ph.D.

      Affiliations

    • Center for Biomaterials & Advanced Technologies, Medical Devices Group, A division of Ethicon, A Johnson & Johnson Company, Somerville, New Jersey
  • ,
  • Janel Young, B.S.

      Affiliations

    • Johnson & Johnson Pharmaceutical Research & Development, L.L.C., Raritan, New Jersey
  • ,
  • Scott Wadsworth, Ph.D.

      Affiliations

    • Johnson & Johnson Pharmaceutical Research & Development, L.L.C., Raritan, New Jersey
  • ,
  • Helen Cui

      Affiliations

    • Center for Biomaterials & Advanced Technologies, Medical Devices Group, A division of Ethicon, A Johnson & Johnson Company, Somerville, New Jersey
  • ,
  • Gere S. diZerega, M.D.

      Affiliations

    • University of Southern California, Keck School of Medicine, Department of Obstetrics & Gynecology, Livingston Reproductive Biology Laboratories, Los Angeles, California
    • Corresponding Author InformationTo whom correspondence and reprint requests should be addressed at Department of Obstetrics & Gynecology, University of Southern California, Keck School of Medicine, Livingston Reproductive Biology Laboratories, 1321 N. Mission Road, Los Angeles, CA 90033.
  • ,
  • Kathleen E. Rodgers, Ph.D.

      Affiliations

    • University of Southern California, Keck School of Medicine, Department of Obstetrics & Gynecology, Livingston Reproductive Biology Laboratories, Los Angeles, California

Received 30 March 2006 published online 11 June 2007.

Background

Preclinical studies using the rabbit sidewall and double uterine horn models were used to assess time and dose response of tranilast delivered via subcutaneous pump, p.o., or as an intraperitoneal bolus in viscoelastic gels as well as an intraperitoneal biodegradable poly(p-dioxanone) fiber in reducing adhesions compared to vehicle controls.

Materials and methods

New Zealand white rabbits underwent laparotomy followed by: 1) uterine horn abrasion and peripheral devascularization or 2) cecal abrasion and sidewall deperitonealization. Tranilast treatment using various vehicles and dosages was compared to vehicle alone versus no treatment. Animals were euthanized after 7 to 21 days. Adhesion formation was assessed by two independent observers.

Results

There were reductions in adhesion formation when drug was delivered topically, but oral drug alone was not effective. When tranilast was given preoperatively, oral drug added to the adhesion reduction of intraperitoneal administered drug. Tranilast in a viscoelastic carrier as well as in a biodegradable fiber was effective at reducing adhesions in the double uterine horn model. The slow release of tranilast from a biodegradable rod produced overall the best results. There were no safety issues.

Conclusion

Tranilast was effective in reducing adhesions when given in a variety of vehicles in different rabbit models of adhesion formation. Overall, the sustained intraperitoneal delivery of tranilast from biodegradable fibers was the most suitable for clinical testing.

Key Words: adhesion prevention, tranilast

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0022-4804(06)00263-0

doi:10.1016/j.jss.2006.05.044

Journal of Surgical Research
Volume 141, Issue 2 , Pages 153-161, August 2007