Journal of Surgical Research
Volume 148, Issue 2 , Pages 136-142, August 2008

Application of a New Type of Sutureless Magnetic Biliary-Enteric Anastomosis Stent for One-Stage Reconstruction of the Biliary-Enteric Continuity After Acute Bile Duct Injury: An Experimental Study

  • Jianhui Li, M.D.
  • ,
  • Yi Lü, M.D., Ph.D.

      Affiliations

    • Corresponding Author InformationTo whom correspondence and reprint requests should be addressed at Department of Hepatobiliary Surgery, The First Affiliated Hospital, School of Medicine, Xi'an Jiaotong University, Xi'an 710061, China.
  • ,
  • Bo Qu, Ph.D.
  • ,
  • Zhiyong Zhang, M.D.
  • ,
  • Chang Liu, Ph.D.
  • ,
  • Yuan Shi, Ph.D.
  • ,
  • Bo Wang, Ph.D.

Department of Hepatobiliary Surgery, The First Affiliated Hospital, School of Medicine, Xi'an Jiaotong University, Xi'an, China

Received 6 April 2007 published online 16 October 2007.

Background

The bile duct cannot be repaired or reconstructed in one stage after 24 h of bile duct injury due to significant inflammation. Even if the bile duct can be repaired, anastomosis is difficult because of the extremely technical nature of the procedure. The traditional method of anastomosis utilizes screw thread. This would increase the inflammatory response, delay anastomotic healing, and lead to the increase in the failure rate. To reconstruct the biliary-enteric continuity under the circumstance of severe inflammation after bile duct injury, we invented a new type of anastomotic apparatus (sutureless magnetic stent) for cholangiojejunostomy. The objective of this study was to evaluate the effect of a new type of sutureless magnetic biliary-enteric anastomosis stent, which was used to reconstruct the biliary-enteric continuity in one stage. The reconstruction was conducted under the circumstance of severe inflammation after acute bile duct injury in dogs.

Methods

We used a model of acute bile duct injury and bile peritonitis in dogs. The sutureless magnetic biliary-enteric anastomosis stents was used to reconstruct the biliary-enteric continuity in one stage under the circumstance of a bile duct with severe inflammation. The effect of stents was observed. Cholangiography and anastomotic histology were examined at 1 mo and compared with traditional manual anastomosis.

Results

Anastomotic stents were used to reconstruct the biliary-enteric continuity in one stage in dogs. No anastomotic leak or infection occurred. Cholangiography showed that the anastomosis was unobstructed. Histological examinations showed that the anastomosis healed well, the inflammatory reaction was small, and collagen fibers lined up in order. There was high incidence of bile leakage in the conventional suture group. Cholangiography showed that anastomotic stenosis was high. Histological examination showed that there was more extensive inflammation around the anastomosis and the collagen fibers were disorganized.

Conclusion

It was safe and feasible to use the new type of anastomosis stent to reconstruct the biliary-enteric continuity in one stage under the circumstance of severe bile duct inflammation after bile duct injury in dogs.

Key Words: magnetic, bile duct injury, cholangiojejunostomy, reconstruction

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0022-4804(07)00557-4

doi:10.1016/j.jss.2007.09.014

Journal of Surgical Research
Volume 148, Issue 2 , Pages 136-142, August 2008