Journal of Surgical Research
Volume 153, Issue 1 , Pages 1-11, 1 May 2009

Computational Modeling of Microarterial Anastomoses With Size Discrepancy (Small-to-Large)

  • Rory F. Rickard, F.R.C.S., F.R.C.S.(Plast)

      Affiliations

    • Royal Naval Medical Service, UK and Department of Plastic Surgery, University of Cape Town, Cape Town, South Africa
    • Corresponding Author InformationTo whom correspondence and reprint requests should be addressed at Canniesburn Unit for Plastic Surgery, Glasgow Royal Infirmary, Glasgow G4 0SF, UK
  • ,
  • Chris Meyer, Ph.D.

      Affiliations

    • Department of Mechanical Engineering, University of Cape Town, Cape Town, South Africa
  • ,
  • Don A. Hudson, F.C.S.(SA), F.R.C.S.

      Affiliations

    • Department of Plastic Surgery, University of Cape Town, Cape Town, South Africa

Received 5 November 2007 published online 12 May 2008.

Objective

Among causes of anastomotic failure in microvascular surgery is vessel size mismatch. Where the option of an end-to-side anastomosis is unavailable, an end-to-end construct must be used. Several end-to-end techniques are described to deal with size mismatch. The aim of this study was to numerically model arterial flow patterns and wall shear stresses in four idealized end-to-end anastomoses, where the upstream or recipient artery is smaller. The four techniques modeled were: an invaginating anastomosis; a fish-mouth incision of the smaller vessel; an oblique section of the smaller vessel; and a wedge excision of the larger vessel.

Materials and methods

Flow rate in the right femoral artery of a single outbred male Wistar rat was recorded by transit time ultrasound. Initially, upstream vessel diameter in the models was set at 1 mm, and downstream at 2 mm. The wedge technique was further modeled using a shorter wedge, and using a downstream vessel diameter of 3 mm. Walls were deemed noncompliant. Flow was modeled by the finite volume method using the commercially available computational fluid dynamics code Fluent (Fluent Inc., Lebanon, NH; http://www.fluent.com).

Results

Ring vortices were seen in the invagination and fish-mouth models and showed similar characteristics, although they were less pronounced in the fish-mouth model. The oblique section model demonstrated complex, spiral, counter-rotating vortices that dissipated downstream. Flow separation was least in the first wedge model, with centralization of flow during high but decelerating flow rate. Shortening the wedge length or increasing the downstream vessel diameter to 3 mm led to flow separation. Wall shear stresses were broadly similar for all constructs.

Conclusion

Of those modeled, excision of a wedge of the larger vessel proved the best construct. Where a vessel diameter ratio is 1:2, wedge length should be twice the diameter of the larger vessel. A vessel ratio of 1:3 leads to flow separation when using the wedge technique.

Key Words: microsurgery, arterial size mismatch, end-to-end anastomosis, computational fluid dynamics, hemodynamics

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0022-4804(08)00142-X

doi:10.1016/j.jss.2008.02.038

Journal of Surgical Research
Volume 153, Issue 1 , Pages 1-11, 1 May 2009